Dikita provided criteria and specifications for injection of sealant to bond concrete members and designed additional steel support brackets and braces attaching column to existing concrete beams and repaired column/beam where chipping and scraping occurred. Dikita also engineered structure drainage improvements to prevent water infiltration onto structural members.